LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> Local Station Data Link Module A1SJ71AT23BQ Hardware User's Manual MITSUBISHI A1SJ71AT23BQ Manual

Local Station Data Link Module A1SJ71AT23BQ Hardware User's Manual MITSUBISHI A1SJ71AT23BQ Manual

Product model: A1SJ71AT23BQ
Name: Local Station Data Link Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
File size: 0.65MB
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 2 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A1SJ71AT23BQ User's Manual A1SJ71AT23BQ A65B/A68B/A55B/A58B connection cable.
Length: 400mm. Enter 32 points.
5mA DC24V.
Response time: 0.3ms.
32 point 1 public.
Output 32 points.
DC12/24V.
Leakage current: 0.1mA OFF.
Response time: 1ms. 32 point 1 public.
Protection function.
Surge.
40 pin connector.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF A1SJ71AT23BQ User's Manual.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A1SJ71AT23BQ User's Manual.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. 5 slots.
To install the power supply MITSUBISHI A1SJ71AT23BQ Manual .
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI A1SJ71AT23BQ Manual .
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three MITSUBISHI A1SJ71AT23BQ Manual .
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
Therre exist input / output hysteresis phenomena, i A1SJ71AT23BQ Hardware. e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A1SJ71AT23BQ User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.