LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> I/O MODULE AJ35TC1-32DT Manual MITSUBISHI AJ35TC1-32DT User's Manual

I/O MODULE AJ35TC1-32DT Manual MITSUBISHI AJ35TC1-32DT User's Manual

Product model: AJ35TC1-32DT
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 6.99MB
26 point with the connection transformation adapter 16 type 1 point input CC-Link unit to install the special connection transformation adapterMITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust AJ35TC1-32DT Manual .
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step AJ35TC1-32DT
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Output points: 16 points.
Voltage: DC24/48V AJ35TC1-32DT Manual .
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 3ms.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ35TC1-32DT Manual .
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program MITSUBISHI AJ35TC1-32DT User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions MITSUBISHI AJ35TC1-32DT User's Manual.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI AJ35TC1-32DT User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control reqquirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ35TC1-32DT .
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ35TC1-32DT Manual .
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
DC input / transistor output module
AJ65SBTB1-32DT
MITSUBISHI DC input / transistor output module AJ65SBTB1-32DT
Input type: DC input, positive common end. In
MITSUBISHI
Transistor output module
AJ35TC1-32T
MITSUBISHI Transistor output module
 AJ35TC1-32T
Output points: 32 points. Output voltage and
MITSUBISHI
DC input / transistor output module
AJ35TC1-32DT
MITSUBISHI DC input / transistor output module AJ35TC1-32DT
DC input points: 16 points. Input voltage and