LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> E5AN-CY3BT-N Manual OMRON E5AN-CY3BT-N INSTRUCTION Manual

E5AN-CY3BT-N Manual OMRON E5AN-CY3BT-N INSTRUCTION Manual

Product model: E5AN-CY3BT-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
File size: 1.84MB
Size: 96 x 96mm.
Control output 1: double relay (proportional valve).
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications OMRON E5AN-CY3BT-N INSTRUCTION Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5AN-CY3BT-N
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately) OMRON E5AN-CY3BT-N INSTRUCTION Manual.
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control OMRON E5AN-CY3BT-N INSTRUCTION Manual. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 300mmm.
Output mode: NPN output. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E5AN-CY3BT-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-CY3BT-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Foundation type temperature controller
E5AN-C1T-N
OMRON Foundation type temperature controller E5AN-C1T-N
Size: 96 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5AN-C3BBFL-N
OMRON Foundation type temperature controller E5AN-C3BBFL-N
Size: 96 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5AN-CY3T-N
OMRON Foundation type temperature controller E5AN-CY3T-N
Size: 96 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5AN-C1T-W-N
OMRON Foundation type temperature controller E5AN-C1T-W-N
Size: 96 x 96mm. Ontology: terminal type, tem