LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> E5AC-CC2DSM-005 INSTRUCTION Manual OMRON E5AC-CC2DSM-005 Manual

E5AC-CC2DSM-005 INSTRUCTION Manual OMRON E5AC-CC2DSM-005 Manual

Product model: E5AC-CC2DSM-005
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
File size: 0.93MB
Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver OMRON E5AC-CC2DSM-005 Manual.
Control output 1: output unit mode.
Control output 2: output unit mode E5AC-CC2DSM-005
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products OMRON E5AC-CC2DSM-005 Manual.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors OMRON E5AC-CC2DSM-005 Manual.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 30 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 1 m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly E5AC-CC2DSM-005 INSTRUCTION Manual.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axiss offset of less than ±2 E5AC-CC2DSM-005 INSTRUCTION Manual. 5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.
Related products
OMRON
Digital temperature controller
E5AC-CC2DSM-014
OMRON Digital temperature controller E5AC-CC2DSM-014
Size: 96 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5AC-CC4DSM-005
OMRON Digital temperature controller E5AC-CC4DSM-005
Size: 96 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5AC-CC4DSM-013
OMRON Digital temperature controller E5AC-CC4DSM-013
Size: 96 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5CC-CX2DSM-005
OMRON Digital temperature controller E5CC-CX2DSM-005
Size: 48 x 48mm. Control output 1: linear cu