Product model: E3S-AD31
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Appearance: L-shaped.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Light-ON.
Indicator mode: No incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting OMRON E3S-AD31 INSTRUCTION sheet.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC E3S-AD31 Size: Shielded, M18.
Sensing distance: 5 mm.
Model: Output configuration: NPN NC.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe OMRON E3S-AD31 INSTRUCTION sheet.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E3S-AD31 INSTRUCTION sheet.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Modeels available with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E3S-AD31 Manual.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications E3S-AD31 Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
Related products
OMRON
Amplifier built-in type photoelectric switch
E3S-BD61
OMRON Amplifier built-in type photoelectric switch E3S-BD61
Small, easy to use. Detection mode: diffuse r
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD23
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD23
Sensing method: Diffuse-reflective Sensors.
OMRON
Transparent Object Detection Sensor
E3S-R66
OMRON Transparent Object Detection Sensor E3S-R66
Sensing method: Retro reflective. Appearance
OMRON
Oil-resistant, Long-range Photoelectric Sensor
E3S-CD11
OMRON Oil-resistant, Long-range Photoelectric Sensor  E3S-CD11
Sensing method: Diffuse-reflective. Appearan