LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> D4NH-8CAS Manual OMRON safety-door hinge switch D4NH-8CAS INSTRUCTION sheet

D4NH-8CAS Manual OMRON safety-door hinge switch D4NH-8CAS INSTRUCTION sheet

Product model: D4NH-8CAS
Name: safety-door hinge switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.47MB
Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment OMRON safety-door hinge switch INSTRUCTION sheet D4NH-8CAS
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Actuator: Roller lever (resin lever, bearing roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches OMRON safety-door hinge switch INSTRUCTION sheet.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON safety-door hinge switch INSTRUCTION sheet.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; Pg13 D4NH-8CAS INSTRUCTION sheet. 5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards D4NH-8CAS INSTRUCTION sheet.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4NH-8CAS INSTRUCTION sheet.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Cat whisker.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MMBB contacts are available D4NH-8CAS Manual. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads OMRON safety-door hinge switch INSTRUCTION sheet.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
Related products
OMRON
Safety-door Hinge Switch
D4NH-4DAS
OMRON Safety-door Hinge Switch D4NH-4DAS
Actuator: Shaft. Conduit size: 1-conduit M2
OMRON
Safety-door Hinge Switch
D4NH-8BAS
OMRON Safety-door Hinge Switch D4NH-8BAS
Actuator: Shaft. Conduit size: 2-conduit M2
OMRON
Safety-door Hinge Switch
D4NH-8CAS
OMRON Safety-door Hinge Switch D4NH-8CAS
Actuator: Shaft. Conduit size: 2-conduit M2
OMRON
Safety-door Hinge Switch
D4NH-4FBC
OMRON Safety-door Hinge Switch D4NH-4FBC
Actuator: Arm lever. Conduit size: 1-conduit