AY41-UL User's Manual MITSUBISHI AY41-UL Manual

Product model: AY41-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.41MB
RS-422 1 channel.
Transfer speed: 19.2/38.4bps.
AJ71C22-S1/A0J2-C214-S1 connection.
Input and output module connected with A0J2.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points MITSUBISHI AY41-UL Manual AY41-UL
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book MITSUBISHI AY41-UL Manual . Using A1SJ71LP21 and A1SJ71BR11MELSECNET/10 modules,
Can be any ANSCPU module to the network system.
Two options can be provided; the optical cable token ring network and the coaxial cable token bus network.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI AY41-UL Manual .
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Input type: AC.
Input points: 16 points.
Input voltage: AC200-240V.
Input current: 9mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming languagee is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-tto-one correspondence between the ladder diagram and the ladder diagram AY41-UL User's Manual AY41-UL User's Manual. Its characteristics are basically consistent with the ladder diagram language.
Related products
MITSUBISHI
Transistor output module
AY41P
MITSUBISHI Transistor output module AY41P
Output points: 32 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY42-S1
MITSUBISHI Transistor output module AY42-S1
Output points: 64 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY41
MITSUBISHI Transistor output module AY41
Output points: 32 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY40P
MITSUBISHI Transistor output module AY40P
Output points: 16 points. Voltage: DC12/24V.