LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> A0J2HCPUP21 Programming Manual MITSUBISHI A0J2HCPUP21 Common Instructions Manual

A0J2HCPUP21 Programming Manual MITSUBISHI A0J2HCPUP21 Common Instructions Manual

Product model: A0J2HCPUP21
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 3.29MB
Hardware implementation is mainly to control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection MITSUBISHI A0J2HCPUP21 Manual A0J2HCPUP21
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced. Input points: 32 points.
Input voltage and current: 7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing MITSUBISHI A0J2HCPUP21 Manual.
Output points: 24 points.
Output voltage: DC12V/24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
Output type: transistor output.
8 point /1 a public side.
36 point terminal station.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI A0J2HCPUP21 Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake siignal and fan fault signal A0J2HCPUP21 Programming Manual .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A0J2HCPUP21 Programming Manual .
Related products
MITSUBISHI
CPU unit
A2CCPUP21
MITSUBISHI CPU unit A2CCPUP21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2ACPUP21
MITSUBISHI CPU unit A2ACPUP21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A3NCPUP21
MITSUBISHI CPU unit A3NCPUP21
Input and output points: 2048 points. Input /
MITSUBISHI
CPU unit
A2NCPUP21
MITSUBISHI CPU unit A2NCPUP21
Input and output points: 512 points. Input /