Professional Industrial Control Components Supplier
Mitsubishi, Yaskawa and other top brands, quality guaranteed, in stock

Professional Industrial Control Components Supplier

Series A PLC

Triple Mitsubishi AX11C Input Module

Mitsubishi Input Module AX11C

New
Brand Mitsubishi
Model AX11C
$125.00
Inquiry Now

Mitsubishi Input Module AX11C:

●Input points: 32

●Input voltage: AC 100–120V

●Current: 6mA

●Response time: 30ms

●16 points per common terminal

●50-point terminal block

System program memory stores system programs (management, interpretation, and compilation), is ROM-based, factory-set, non-changeable, and retains data when power is off.

PLC selection: With increasing variety and functionality, choose based on control requirements, performance-to-price ratio, and application suitability.

Scan cycle: Input sampling, program execution, and output refresh are performed centrally. Inputs are sampled only at the start of each scan; new states during execution are read in the next cycle. Outputs are updated at the end.

Scan cycle length depends on:

●CPU instruction speed

●Instruction execution time

●Number of instructions

Due to centralized sampling and output, there is input/output response delay (lag).

Mitsubishi input module AX11C:

●Input points: 32

●Input voltage: AC 100–120V

●Current: 6mA

●Response time: 30ms

●Common terminal: 16 points per common

●Terminal block: 50 points

System program memory: stores system programs (management, interpretation, and compilation), resides in ROM, factory-set, non-changeable, data retained after power-off.

PLC selection: As PLC technology evolves, various models with different performance, applications, and prices are available. Selection should prioritize cost-effectiveness while meeting control requirements.

Each scan cycle: centralized input sampling and output refreshing.

During input refresh, when the input port is closed, new input states during program execution are not read until the next scan.

A scan cycle consists of: input sampling, program execution, and output refresh.

The content of the image register changes with program execution.

Scan cycle duration depends on: CPU execution speed, instruction execution time, and number of instructions.

Due to centralized sampling and output, there is an input/output response delay (lag).

NEED INDUSTRIAL PARTS?

Have questions about industrial components? We'd love to hear from you.

Our experts are ready to assist you in finding the right parts for your industrial automation needs.