Mitsubishi L60TCTT4 End Cover with ERR Terminal: Features & Wiring Guide
Mitsubishi L60TCTT4 Terminal Block with ERR Terminal
Mitsubishi end cover L60TCTT4 with ERR terminal. Error output. Rated switching: DC24V, 0.5A. Min. switching load: DC5V, 1mA. Response time: OFF→ON ≤10ms, ON→OFF ≤12ms. Mechanical life: ≥20 million cycles. Electrical life: ≥100,000 cycles at rated load. Wire size: 0.3–2.0 mm² (AWG22–14), stranded/solid. Connection: spring clamp terminal block. Internal consumption at DC5V: 0.06A. Weight: 0.11kg.
Mitsubishi terminal cover L60TCTT4 with ERR terminal.
Error output.
Rated switching voltage/current: DC24V, 0.5A.
Minimum switching load: DC5V, 1mA.
Response time: OFF→ON ≤10ms; ON→OFF ≤12ms.
Mechanical life: ≥20 million operations.
Electrical life: ≥100,000 operations at rated load.
Wire size: 0.3–2.0 mm² (AWG22–14), stranded/solid.
Connection: spring-clamp terminal block.
Internal consumption at DC5V: 0.06A.
Weight: 0.11 kg.
Have questions about industrial components? We'd love to hear from you.
Our experts are ready to assist you in finding the right parts for your industrial automation needs.