LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HQ2HH03-FLK User's Manual

OMRON E5CN-HQ2HH03-FLK User's Manual

Product model: E5CN-HQ2HH03-FLK
Name: Temperature Controller
Brand: OMRON
Sort: User's Manual
File language: English
File size: 6.25MB
Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - E5CN-HQ2HH03-FLK.
Communication: RS-485.
Event input: 2 points E5CN-HQ2HH03-FLK
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E5CN-HQ2HH03-FLK.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E5CN-HQ2HH03-FLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-HQ2HH03-FLK.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-HQ2HH03-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
High performance temperature controller
E5CN-HQ2HB
OMRON High performance temperature controller E5CN-HQ2HB
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HQ2BFD
OMRON High performance temperature controller E5CN-HQ2BFD
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
High performance temperature controller
E5CN-HQ2H01-W-FLK
OMRON High performance temperature controller E5CN-HQ2H01-W-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Programmed temperature controller
E5CN-HTQ2HH03-FLK
OMRON Programmed temperature controller E5CN-HTQ2HH03-FLK
Size: 48 48mm, terminal type. Category: con