Appearance: M18.
Sensing distance: 10 mm.
Connection method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode : NO .
Pin arrangement: --.
Applicable connector code: --.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E E5AN-HPRR203B-FLK.
Standard Sensors for detecting ferrous metals
E5AN-HPRR203B-FLK
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E5AN-HPRR203B-FLK.
Cable protector provided as a standard feature. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater E5AN-HPRR203B-FLK.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSensing method: Retro-reflective with MSR function.
Connection method: Standard M8 connector.
Sensing distance: 4 m(100 mm).
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly E5AN-HPRR203B-FLK.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axiss offset of less than ±2 E5AN-HPRR203B-FLK. 5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.