Product model: AJ35PTF-56DT
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 6.99MB
I/O slots: 8 slots.
Could you install the power module.
Outline dimension: 420*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate AJ35PTF-56DT User's Manual.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board AJ35PTF-56DT
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection. Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following AJ35PTF-56DT User's Manual.
Rated input voltage / current: DC12V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ35PTF-56DT User's Manual.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Output type: transistor output, drain type MITSUBISHI AJ35PTF-56DT Manual .
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0 MITSUBISHI AJ35PTF-56DT Manual . 5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI AJ35PTF-56DT Manual . Can connect the transmitter units 2 units using radius of about 50 meters (outdoor 200 meters).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MMITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system AJ35PTF-56DT .
The main contents of the initialization program arre: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc AJ35PTF-56DT User's Manual. .
Related products
MITSUBISHI
DC input module
AJ35PTF-32D
MITSUBISHI DC input module AJ35PTF-32D
DC input points: 32 points. Input voltage and
MITSUBISHI
AC input / relay output module
AJ35PTF-28AR
MITSUBISHI AC input / relay output module AJ35PTF-28AR
AC input points: 16 points. Input voltage and
MITSUBISHI
DC input / transistor output module
AJ35PTF-128DT
MITSUBISHI DC input / transistor output module AJ35PTF-128DT
DC input points: 64 points. Input voltage and
MITSUBISHI
AC input / silicon controlled output module
AJ35PTF-56AS
MITSUBISHI AC input / silicon controlled output module AJ35PTF-56AS
AC input points: 32 points. Input voltage and